
methylflash methylated dna quantification kit
Product Choices
The MethylFlash™ Methylated DNA Quantification Bundle (Fluorometric) is a further refinement of our earlier SuperSense™ worldwide DNA methylation quantification kits by simplifying the workflow and enhancing the consistency of outcomes. It makes use of an progressive methodology to permit background alerts to be terribly low, eliminating the plate drying and blocking steps. Compared with chromatography-based methods equivalent to HPLC or mass spectrometry, this product gives an inexpensive answer to exactly measure ranges of 5-methylcytosine. The gear has the following advantages and choices:
Product Overview
The MethylFlash Methylated DNA Quantification Bundle (Fluorometric) is an entire set of optimized buffers and reagents to fluorometrically quantify worldwide DNA methylation by notably measuring ranges of 5-methylcytosine (5-mC) in a microplate-based format. Compared with LUMA or LINE-1, Alu, and LTR-based assays, MethylFlash™ experience straight quantifies exact worldwide DNA methylation.
This gear may also be notably optimized for paired use with the MethylFlash Hydroxymethylated DNA Quantification Bundle (Fluorometric) for concurrently quantifying every methylated DNA and hydroxymethylated DNA.
- Fluorometric assay with easy-to-follow steps for consolation and velocity. All the method may be accomplished inside 4 hours.
- Progressive gear composition permits background alerts to be terribly low, which eliminates the need for plate blocking and permits the assay to be straightforward, right, reliable, and fixed.
- Extreme sensitivity, of which the detection prohibit may be as little as 50 pg of methylated DNA and accepts as little as 20 ng of enter genomic DNA
- Optimized antibody and enhancer choices allow extreme specificity to 5-mC, with no cross-reactivity to unmethylated cytosine and no or negligible cross-reactivity to hydroxymethylcytosine all through the indicated focus fluctuate of the sample DNA.
- Widespread optimistic and unfavourable controls are included, which might be applicable for quantifying methylated DNA from any species.
- Strip-well microplate format makes the assay versatile: information or extreme throughput analysis.
Principle & Course of
The MethylFlash™ Methylated DNA Quantification Bundle (Fluorometric) contains all reagents wanted for the quantification of worldwide DNA methylation. On this assay, DNA is definite to strip wells which may be notably dealt with to have a extreme DNA affinity. The methylated fraction of DNA is detected using seize and detection antibodies after which quantified fluorometrically by finding out the absorbance in a fluorescence microplate spectrophotometer at excitation 530 and emission 590 nm. The amount of methylated DNA is proportional to the RFU (relative fluorescence fashions) measured, which may be calculated with the gear’s included formulation for relative methylation standing of two completely totally different DNA samples or absolute quantification of 5-methylcytosine (5-mC) using a typical curve.
Easy, Fast, and Versatile
All of the fluorometric assay has easy-to-follow steps for consolation and velocity, which may be achieved in 4 hours. The strip-well microplate format permits for a flexible assay in information or extreme throughput analysis. Widespread optimistic and unfavourable controls are included with the gear for quantifying methylated DNA from any species equivalent to mammals, vegetation, fungi, micro organism, and viruses.
Safe and Helpful
All the wished reagents, along with unfavourable controls and optimistic controls, for quantification of worldwide DNA methylation are conveniently packaged inside the gear. The direct fluorometric quantification of DNA samples replaces outdated or inferior methods and eliminates the need for DNA digestion/denaturation, radioactivity, extraction, or chromatography.

Extraordinarily Delicate and Explicit
The novel course of and proprietary gear compositions allow for proper quantification of methylated DNA to be achieved with extreme sensitivity and specificity. The detection prohibit of the enter DNA may be as little as 50 pg of methylated DNA.
MethylFlash (Fluorometric) | Competitor Z | Competitor C | |
---|---|---|---|
Assay Principle | Direct ELISA | Direct ELISA | Indirect ELISA |
Format | 96-well plate | 96-well plate | 96-well plate |
Sensitivity | Superb detection prohibit: 0.05 ng of 5-mC DNA | Good detection prohibit: >0.5 ng of 5-mC DNA | Very poor detection prohibit: >1000 ng of 5-mC DNA |
S/N Ratio | >20 with very low background | <4 with extreme background | N/A* |
Procedural Consolation | No need for plate blocking and denaturation of DNA | Requires plate blocking and DNA denaturation | Requires plate blocking, DNA digestion, and antibody aggressive incubation in an additional plate |
Protocol Time | <4 hr | <4 hr | >eight hr |
DNA Form & Species | Widespread for any species, every ssDNA and dsDNA | Human and mouse ssDNA solely | Quite a few species |
Specificity | Explicit to 5-mC solely | Cross-reaction to 5-hmC | N/A* |
Quantitation Form | Every relative and absolute quantification | Relative | Relative |
Regular Administration | Regular, quantitative in absolute amount of 5-mC, and may be universally used for any species | Unstable, cannot be quantitative in amount, and will solely be used for human or mouse | N/A* |
Minimal Enter Amount | 20 ng | 100 ng | 1000 ng |
Accuracy of Detection | Extreme, regular and quantified customary administration. Confirmed shut correlation with LC-MS analysis by clients | Unclear, unstable and un-quantified customary administration | N/A* |
% 5-mC calculation | Straightforward | Tough | Not Provided |
Patented Method | Certain | No | No |
Status | Very extreme printed citation rely | Low printed citation rely | Low printed citation rely |
Assist Expertise | Since 2006 | Since 2013 | Since 2011 |
Product Choices
The MethylFlash™ Methylated DNA Quantification Bundle (Colorimetric) is a further refinement of our earlier Methylamp™ worldwide DNA methylation quantification kits by simplifying the workflow and enhancing the consistency of outcomes. It makes use of an progressive methodology to permit background alerts to be terribly low, eliminating the plate drying and blocking steps. Compared with chromatography-based methods equivalent to HPLC or mass spectrometry, this product gives an inexpensive answer to exactly measure ranges of 5-methylcytosine. The gear has the following advantages and choices:
- Colorimetric assay with easy-to-follow steps for consolation and velocity. All the method may be accomplished inside 4 hours.
- Progressive gear composition permits background alerts to be terribly low, which eliminates the need for plate blocking and permits the assay to be straightforward, right, reliable, and fixed.
- Extreme sensitivity, of which the detection prohibit may be as little as 0.2 ng of methylated DNA and accepts as little as 50 ng of enter genomic DNA.
- Optimized antibody and enhancer choices allow extreme specificity to 5mC, with no cross-reactivity to unmethylated cytosine and no or negligible cross-reactivity to hydroxymethylcytosine all through the indicated focus fluctuate of the sample DNA.
- Widespread optimistic and unfavourable controls are included, which might be applicable for quantifying methylated DNA from any species.
- Strip-well microplate format makes the assay versatile: information or extreme throughput analysis.
![]() Methylamp Universal Methylated DNA Kit |
|||
P-1011 | EpiGentek |
|
|
![]() Methylamp PCR Enhancer |
|||
R-1002 | EpiGentek |
|
|
![]() Methylamp 96 DNA Modification Kit |
|||
P-1008 | EpiGentek |
|
|
![]() Methylamp Methylated DNA Capture (MeDIP) Kit |
|||
P-1015 | EpiGentek |
|
|
![]() Methylamp RNA Bisulfite Conversion Kit |
|||
P-9003 | EpiGentek |
|
|
![]() Methylamp Universal Methylated DNA Preparation Kit |
|||
P-1019 | EpiGentek | 40 µg | EUR 416.7 |
![]() Methylamp One-Step DNA Modification Kit |
|||
P-1010 | EpiGentek |
|
|
![]() Methylamp Whole Cell Bisulfite Modification Kit |
|||
P-1016 | EpiGentek |
|
|
![]() Methylamp Coupled DNA Isolation & Modification Kit |
|||
P-1002 | EpiGentek | 40 Samples | EUR 474.12 |
![]() Methylamp Global DNA Methylation Quantification Ultra Kit |
|||
P-1014B | EpiGentek |
|
|
![]() Fast Eva QPCR SuperMix Kit |
|||
K5052002 | Biochain | 200 rxn | EUR 188 |
![]() Fast Pro QPCR SuperMix Kit - ROX premixed |
|||
K5058200 | Biochain | 200 reactions | EUR 188 |
![]() Fast Pro QPCR SuperMix Kit - ROX premixed |
|||
K5058400 | Biochain | 400 reactions | EUR 316 |
![]() Fast EvaGreen Master Mix for qPCR (5000 rxn) |
|||
31003-2 | Biotium | 50x1ML | EUR 3739.2 |
Description: Minimum order quantity: 1 unit of 50x1ML |
![]() Genious 2X SYBR Green Fast qPCR Mix |
|||
RK21204 | Abclonal | 1 mL | Ask for price |
![]() 2X Universal SYBR Green Fast qPCR Mix |
|||
RK21203 | Abclonal | 1 mL | Ask for price |
![]() Fast EvaGreen Master Mix for qPCR(200 rxn) |
|||
31003 | Biotium | 2x1ML | EUR 244.8 |
Description: Minimum order quantity: 1 unit of 2x1ML |
![]() Fast EvaGreen Master Mix for qPCR (500 rxn) |
|||
31003-1 | Biotium | 5x1ML | EUR 463.2 |
Description: Minimum order quantity: 1 unit of 5x1ML |
![]() Fast Plus EvaGreen qPCR Master Mix (500 rxn) |
|||
31020-1 | Biotium | 5x1mL | EUR 524.4 |
Description: Minimum order quantity: 1 unit of 5x1mL |
![]() Fast Plus EvaGreen qPCR Master Mix (5000 rxn) |
|||
31020-2 | Biotium | 50x1mL | EUR 4291.2 |
Description: Minimum order quantity: 1 unit of 50x1mL |
![]() Genious 2X SYBRGREEN FAST qPCR MIX (Low ROX) |
|||
RK21206 | Abclonal | 1 ml | Ask for price |
![]() Genious 2X SYBR GREEN FAST qPCR MIX (No ROX) |
|||
RK21205 | Abclonal | 1 ml | Ask for price |
![]() Fast EvaGreen Master Mix for qPCR, trial size (100 rxn) |
|||
31003-T | Biotium | 1ML | EUR 147.6 |
Description: Minimum order quantity: 1 unit of 1ML |
![]() Fast Plus EvaGreen qPCR Master Mix (trial size, 100 rxn) |
|||
31020-T | Biotium | 1mL | EUR 160.8 |
Description: Minimum order quantity: 1 unit of 1mL |